logo
Zhongshan Vangood Appliances Mfg Co., Ltd.
Produk
Produk
Rumah > Produk > Aksesoris Boiler Gas > Wall Mounted Boiler Gas Filter Fuel Purification Component Durable Clog Resistant Model

Wall Mounted Boiler Gas Filter Fuel Purification Component Durable Clog Resistant Model

Rincian produk

Tempat asal: Cina

Nama merek: Vanka

Sertifikasi: ISO9001:2015,CE

Syarat Pembayaran & Pengiriman

Kuantitas min Order: 50 set

Harga: $0.3-$0.6 Sets

Kemasan rincian: 570x340x165

Waktu pengiriman: 30 hari kerja

Syarat-syarat pembayaran: L/C,T/T,Western Union,MoneyGram

Menyediakan kemampuan: Set/set 20000 per bulan

Dapatkan Harga Terbaik
Menyoroti:
Kesesuaian:
Cocok untuk sebagian besar model ketel gas
Komponen inti:
Tembaga
Tegangan Masukan:
220V
Fitur:
Mudah dipasang, tahan lama
Nama Produk:
Aksesoris Boiler Gas
Kompatibel dengan:
Gas alam dan gas LP
Layanan garansi:
1 Tahun
Ukuran Pelabuhan:
KEBIASAAN
Kesesuaian:
Cocok untuk sebagian besar model ketel gas
Komponen inti:
Tembaga
Tegangan Masukan:
220V
Fitur:
Mudah dipasang, tahan lama
Nama Produk:
Aksesoris Boiler Gas
Kompatibel dengan:
Gas alam dan gas LP
Layanan garansi:
1 Tahun
Ukuran Pelabuhan:
KEBIASAAN
Wall Mounted Boiler Gas Filter Fuel Purification Component Durable Clog Resistant Model
Wall Mounted Boiler Gas Filter Fuel Purification Component Durable Clog Resistant Model
The Wall Mounted Boiler Gas Filter is a professional-grade fuel purification component engineered to protect sensitive boiler systems from gas line contaminants. Designed with industrial durability and clog-resistant technology, this essential safeguard ensures consistent gas flow, optimizes combustion efficiency, and extends the operational lifespan of wall-mounted heating systems in residential and commercial applications.
Key Features
  • Advanced Multi-Stage Filtration: Incorporates a precision stainless steel mesh screen (primary) and sintered brass element (secondary) to capture particulates, pipeline debris, and moisture droplets as small as 40 microns.

  • Engineered Clog Resistance: Features a large surface-area filter element and optimized flow design that maintains stable pressure drop, significantly extending service intervals and preventing flow restriction under high-load conditions.

  • Robust Construction for Pressure: Built with a forged brass body and reinforced polymer housing rated for continuous operation at pressures up to 4 bar (58 psi), ensuring reliability in variable gas supply networks.

  • Universal Compatibility: Designed as a direct inline component compatible with natural gas (G20/G25) and LPG systems for most major brands of wall-mounted condensing and conventional boilers.

  • Maintenance-Friendly Design: Includes a transparent polycarbonate sediment bowl (on applicable models) for visual dirt inspection and a bottom drain valve for easy purging without system disassembly.

Technical Specifications
Parameter Specification
Product Type Inline Gas Filter / Fuel Purifier
Application Wall-Mounted Gas Boilers & Water Heaters
Filter Grade (Filtration Level) 40 microns (nominal)
Body Material Forged Brass (DZR)
Filter Element Stainless Steel Mesh + Sintered Brass
Connection Size ¾" BSPP (Female) (Standard), 1" BSPP available
Maximum Operating Pressure 4 bar (58 psi)
Temperature Range -10°C to +80°C
Frequently Asked Questions

Q1: Why is a gas filter necessary for my wall-mounted boiler?
A: Gas supplied from mains can contain microscopic rust particles, pipeline dust, moisture, and installation debris. These contaminants can clog the boiler's gas valve, burners, and injectors, leading to inefficient combustion, ignition failure, increased maintenance costs, and potential safety shutdowns. This filter acts as the first line of defense.

Q2: How often does the filter need to be cleaned or replaced?
A: The maintenance interval depends on local gas quality and system usage. As a general guideline:

  • Inspection/Cleaning: Check the sediment bowl visually every 6-12 months. If significant debris is visible, shut off the gas supply, depressurize, and clean the bowl and filter element.

  • Element Replacement: The durable sintered element typically lasts 3-5 years under normal conditions. Reduced boiler performance or higher-than-normal gas pressure readings may indicate a clogged filter needing attention.

Q3: Can I install this filter myself?
A: Installation involves working with gas piping. We strongly recommend that installation and any maintenance be performed only by a qualified and certified gas engineer or plumber to ensure a gas-tight connection and compliance with local safety regulations. Always turn off the gas supply at the main valve before attempting any work.

Q4: Is it suitable for both natural gas and LPG (propane) systems?
A: Yes, the materials and design are compatible with both standard natural gas (methane) and Liquefied Petroleum Gas (LPG, such as propane). However, ensure your installer confirms the pressure settings and seals are appropriate for your specific gas type, as LPG systems often operate at a higher pressure.